Saving the number of axes found
The CFX11A.. gateway and CFC11A communication modules automatically address all stations (1 – 8) each time the voltage is switched on. This procedure cannot be deactivated.
When auto-addressing has been successfully completed, press and hold pushbutton T1 for at least two seconds. The number of axes found is now saved.
If a number of axes has already been saved in the gateway and a different number of stations is detected, the gateway reports fault 33.21. If the pushbutton is pushed again for two seconds while a fault is pending, the fault is reset and the new number of stations is adopted as the target configuration.