Rotating the connection box

SEW-EURODRIVE always recommends purchasing the prefabricated MOVIMOT® drive with the correct position of cable entries. In exceptional cases, the position of the cable entries can be rotated to the opposite side (only for units with a modular connection box).

WARNING

Electric shock from capacitors that have not been fully discharged.
Severe or fatal injuries.
  • Disconnect the inverter from the power. Observe the minimum switch-off time after disconnection from the supply system:
    • 1 minute
  1. Label the connections of the MOVIMOT® inverter before disconnecting them for later re-installation.
  2. Disconnect the supply system, control, and sensor connections.
  3. Remove the screws [1] and take off the MOVIMOT® inverter [2] from the terminal box.
  4. Loosen the screws [3] and remove the connection box [4].
  5. Turn the connection box [4] by 180°.
  6. Place the connection box [4] on the mounting plate [5] and secure it using 4 screws [3].
  7. Restore the connections.
  8. Place the MOVIMOT® inverter [2] onto the connection box and secure it using 4 screws [1].