Rotating the connection box
SEW-EURODRIVE always recommends purchasing the prefabricated MOVIMOT® drive with the correct position of cable entries. In exceptional cases, the position of the cable entries can be rotated to the opposite side (only for units with a modular connection box).

WARNING

Electric shock from capacitors that have not been fully discharged.
Severe or fatal injuries.
- Disconnect the inverter from the power. Observe the minimum switch-off time after disconnection from the supply system:
- 1 minute
- Label the connections of the MOVIMOT® inverter before disconnecting them for later re-installation.
- Disconnect the supply system, control, and sensor connections.
- Remove the screws [1] and take off the MOVIMOT® inverter [2] from the terminal box.
- Loosen the screws [3] and remove the connection box [4].
- Turn the connection box [4] by 180°.
- Place the connection box [4] on the mounting plate [5] and secure it using 4 screws [3].
- Restore the connections.
- Place the MOVIMOT® inverter [2] onto the connection box and secure it using 4 screws [1].