Drive ID module

The pluggable drive ID module is installed in the basic unit.

The following figure shows the Drive ID module and its position in the MOVIMOT® inverter.

[1]

Drive ID module

The drive ID module contains a memory module on which the following information is saved:

  • Motor data
  • Brake data
  • User parameter

If a MOVIMOT® inverter has to be replaced, you can re-startup the system by simply re-plugging the Drive ID module without a PC/laptop or data backup.

If, during a device replacement

  • the DIP switch setting is not transmitted correctly,
  • or a MOVIMOT® inverter with a different part number is used (e.g. with a different device power),

the MOVIMOT® inverter detects a change in configuration. This may reinitialize certain startup parameters.

This is why the MOVIMOT® inverter must only be replaced with a MOVIMOT® inverter with the same part number.

For information on device replacement, refer to chapter Unit replacement.