Drive ID module
The pluggable drive ID module is installed in the basic unit.
The following figure shows the Drive ID module and its position in the MOVIMOT® inverter.

[1] | Drive ID module |
The drive ID module contains a memory module on which the following information is saved:
- Motor data
- Brake data
- User parameter
If a MOVIMOT® inverter has to be replaced, you can re-startup the system by simply re-plugging the Drive ID module without a PC/laptop or data backup.
If, during a device replacement
- the DIP switch setting is not transmitted correctly,
- or a MOVIMOT® inverter with a different part number is used (e.g. with a different device power),
the MOVIMOT® inverter detects a change in configuration. This may reinitialize certain startup parameters.
This is why the MOVIMOT® inverter must only be replaced with a MOVIMOT® inverter with the same part number.
For information on device replacement, refer to chapter Unit replacement.