Electrical data ECG-

 

-IA2M

-A2M

-A4M

Commutation

Internal

External

External

Voltage

DC 24 V

DC 24 V

DC 48 V

Nominal mechanical output power

40 W (2-stage) applies at 20 °C, observe derating curve

36 W (3-stage) applies at 20 °C, observe derating curve

50 W applies at 20 °C, observe derating curve

65 W (2-stage) applies at 20 °C, observe derating curve

58 W (3-stage) applies at 20 °C, observe derating curve

Nominal current

2.5 A

3.0 A

1.9 A

Maximum overload capacity

160% for max. 5 s

240% for max. 60 s

223% for max. 60 s

Holding brake

Optional

Low-temperature design

x

x

x

Degree of protection

IP54

Installation altitude

≤ 1000 m no restrictions

> 1000 m observe derating, contact SEW-EURODRIVE

Ambient temperatures

-30 °C – +40 °C

Humidity

10 – 90%, non-condensing

Maximum motor cable length

5 mDerating: 1 W per m, from 2 m cable length at nominal load