FCBs that can be activated for selected control mode
FCB | Designation | V/f | VFCPLUS | CFC | ELSM® |
|---|---|---|---|---|---|
01 | Output stage inhibit |
|
|
|
|
02 | Default stop |
|
|
|
|
03 | Profile velocity mode (pv, CiA402) |
|
|
|
|
04 | Manual mode |
|
|
|
|
05 | Speed control |
|
|
|
|
06 | Interpolated speed control |
|
|
|
|
07 | Torque control | – |
|
|
|
08 | Interpolated torque control | – |
|
|
|
13 | Stop at application limits |
|
|
|
|
14 | Emergency stop |
|
|
|
|
15 | Cyclic synchronous velocity mode (csv, CiA402) |
|
|
|
|
17 | Cyclic synchronous torque mode (cst, CiA402) | – |
|
|
|
26 | Stop at user limits (speed-controlled mode) |
|
|
|
|
FCBs that require a parameterized position encoder: | |||||
04 | Manual mode (position-controlled modes) | – |
|
| – |
09 | Position control | – |
|
| – |
10 | Interpolated position control | – |
|
| – |
12 | Reference travel | – |
|
| – |
16 | Cyclic synchronous position mode (csv, CiA402) | – |
|
| – |
19 | Position hold control | – |
|
| – |
20 | Jog | – |
|
| – |
21 | Brake test | – |
|
| – |
23 | Brake test safety card | – |
|
| – |
24 | Profile position mode (pp, CiA402) | – |
|
| – |
26 | Stop at user limits (position-controlled mode) | – |
|
| – |
FCBs that can be activated independently by the control mode: | |||||
25 | Motor parameter measurement |
|
|
|
|