Asynchronous motors in CFC control mode
In comparison to the VFCPLUS control mode, higher dynamic properties can be achieved using CFC. The full motor magnetization is maintained in each operating state, so that the highest dynamic requirements are met. Due to the voltage reserves required for this, standard asynchronous motors are operated with a lower base speed in this operating mode than in the VFCPLUS operating mode. Power yield and energy efficiency are consequently lower. The maximum dynamics of the speed control loop are reached with a high-resolution encoder. The speed setting range depends heavily on the encoder system used