Two-row structure with limited control cabinet width

If the width of the control cabinet is limited, modules can be installed in 2 rows, one above the other. The distance between the main row and the auxiliary row is fixed. Only a limited number of modules and limited module types are allowed in the auxiliary row. The connection between main row and auxiliary row is made with connection units and cable sets for DC link connection.

Different variants of the two-row setup are possible. Project planning must be carried out before installation.

The following image shows a basic configuration of MOVIDRIVE® modular with the two-row setup with limited control cabinet width.

[1]

MDC90A.. capacitor module

[2]

MDD9.A.. double-axis modules

[3]

MDA90A..single-axis modules

[4]

UHX45A/MDM90A master module

[5]

MDP90.. power supply module with braking resistor

[6]

MDA90A..single-axis modules

[7]

MDA90A.. single-axis modules and MDD9.A.. double-axis modules