Available startups
Option | Meaning | Available for |
|---|---|---|
With MOVILINK® DDI data | The motor is automatically started up during initial startup. The motor data is read out electronically and transferred to the selected drive train and can be adjusted if necessary. | SEW motors with MOVILINK® DDI. |
With electronic nameplate | The motor data is read out electronically and transferred to the selected drive train and can be adjusted if necessary. | SEW motors with encoders that have an electronic nameplate, e.g. AK0H. |
Without electronic nameplate | The keypad contains a catalog in which all data about SEW motors is stored. After selecting the motor, the standard data is loaded automatically and can be adjusted if necessary.
| SEW motors |
Third-party asynchronous motor | You must enter the motor data manually. | All asynchronous motors |
Third-party synchronous motor | You must enter the motor data manually. | All synchronous motors. |
MOVILINK® DDI data Restore
| The motor data is read out again and transferred to the drive train. Previously manually changed data is overwritten. | SEW motors with MOVILINK® DDI |
SmartDrive | SmartDrive startup provides country-specific basic startup for an asynchronous motor with typical key data that is adapted to the inverter's power. | Power-adjusted asynchronous motor |