F-communication when activated

The F-communication when activated parameter defines the behavior of safe communication with the higher-level safety controller when the prioritized terminal control is activated.

Parameters

Setting

Meaning

F-communication when activated

Yes

Safe communication is interrupted when the prioritized terminal control is activated.

The signals of the higher-level safety controller are no longer active on the inverter.

This causes the safety option to signal a safe communication timeout error and the safety subfunctions are activated.

 

The "Muting F-PO" function can be used to deactivate the safety subfunctions and thus enable the drive again.

No

Safe communication is not interrupted when the prioritized terminal control is activated.

The signals of the higher-level safety controller are still active on the inverter.