Formula 2.9: Calculation of the number of permitted emergency stop braking operations until brake maintenance

Horizontal and vertical upward

Vertical downward

[NB2] = 1

Number of permitted emergency-stop braking operations until brake maintenance

[NB2max] = 1

Maximum permitted number of emergency-stop braking operations until end of service life

[Winsp] = J

Permitted work until brake maintenance

[fv] = 1

Wear factor. Determined based on the applied load range for braking work.