Example

Brakemotor: DRN80M4 with BE1 brake as line-powered drive

No-load starting frequency Z0 with BGE brake rectifier = 8200 h-1

  1. (JL + JG + JZ) / JM = 3.5 →  KJ = 0.2
  2. ML / MH = 0.6 →  KM = 0.4
  3. Pstat / PN = 0.6 and 60% cdf →  KP = 0.65

 

Z = Z0 × KJ × KM × KP = 8200 h-1 × 0.2 × 0.4 × 0.65 = 426 h-1

The cycle duration is 8.45 s.

The switch-on time amounts to 5.07 s.