Number of testable brakes

A maximum of 2 brakes can be tested separately for each CS..A safety option. They are assigned via the functional assignment of the F-DO.. safe digital outputs.

F-DO..

F-DO function

Meaning for SBT

F-DO00

None

STO

SBC

SBT not available

SBT not available

SBT can be configured for a brake

F-DO01

None

STO

SBC

SBT not available

SBT not available

SBT can be configured for a brake

If F-DO00 and F-DO01 are set to "SBC", the brake test is carried out for 2 brakes. The brake test first tests brake 1 (F-DO00) and automatically repeats test steps 3 to 5 for brake 2 (F-DO01). With 2 brakes, brake 1 and brake 2 are tested with the same test parameters (default setting). You can also set individual test parameters for brake 2.

INFORMATION

In the "Brake test" menu, the settings of the test parameters for brake 2 are only displayed if both F-DO. digital outputs are set with the SBC function.