Derating due to the line voltage and temperature

INFORMATION

Interpolate linearly for voltages between 400 V and 500 V.

INFORMATION

Operation above 40 °C is only possible when using the "Extended temperature range /C1." option.

The following table shows the values for derating as a function of the line voltage Uline and ambient temperature T:

Inverter

fPWM

Continuous current Icont

Uline: 3 × 400 V

Uline: 3 × 500 V

MPX..-0055-..-C

4 kHz

Icont/IN = 136% - (T - 40 °C) × 0.45%

Icont/IN = 136% - (T - 40 °C) × 2.73%

8 kHz

Icont/IN = 136% - (T - 40 °C) × 2.64%

Icont/IN = 127% - (T - 40 °C) × 4.55%

16 kHz

Icont/IN = 96% - (T - 40 °C) × 3.27%

not possible

MPX..-0070-..-C

4 kHz

Icont/IN = 136% - (T - 40 °C) × 1.79%

Icont/IN = 136% - (T - 40 °C) × 3.57%

8 kHz

Icont/IN = 136% - (T - 40 °C) × 3.50%

Icont/IN = 106% - (T - 40 °C) × 3.86%

16 kHz

Icont/IN = 97% - (T - 40 °C) × 3.64%

not possible

MPX..-0095-..-C

4 kHz

Icont/IN = 133% - (T - 40 °C) × 2.95%

Icont/IN = 105% - (T - 40 °C) × 2.89%

8 kHz

Icont/IN = 101% - (T - 40 °C) × 2.63%

Icont/IN = 78% - (T - 40 °C) × 2.84%

16 kHz

Icont/IN = 72% - (T - 40 °C) × 2.68%

not possible

MPX..-0125-..-C

4 kHz

Icont/IN = 140% - (T - 40 °C) × 2.00%

Icont/IN = 132% - (T - 40 °C) × 3.60%

8 kHz

Icont/IN = 128% - (T - 40 °C) × 3.20%

Icont/IN = 99% - (T - 40 °C) × 3.68%

16 kHz

Icont/IN = 80% - (T - 40 °C) × 3.00%

not possible

MPX..-0160-..-C

4 kHz

Icont/IN = 121% - (T - 40 °C) × 2.13%

Icont/IN = 103% - (T - 40 °C) × 2.81%

8 kHz

Icont/IN = 100% - (T - 40 °C) × 2.50%

Icont/IN = 78% - (T - 40 °C) × 2.88%

16 kHz

Icont/IN = 63% - (T - 40 °C) × 2.34%

not possible

MPX..-0240-..-C

4 kHz

Icont/IN = 133% - (T - 40 °C) × 3.13%

Icont/IN = 95% - (T - 40 °C) × 3.06%

8 kHz

Icont/IN = 100% - (T - 40 °C) × 2.60%

Icont/IN = 63% - (T - 40 °C) × 2.50%

16 kHz

Icont/IN = 52% - (T - 40 °C) × 2.81%

not possible

MPX..-0320-..-C

 

4 kHz

Icont/IN = 100% - (T - 40 °C) × 2.34%

Icont/IN = 71% - (T - 40 °C) × 2.30%

8 kHz

Icont/IN = 75% - (T - 40 °C) × 1.95%

Icont/IN = 47% - (T - 40 °C) × 1.88%

16 kHz

Icont/IN = 39% - (T - 40 °C) × 2.11%

not possible

MPX..-0320-..-C
with external fan (MPI../C12)

 

4 kHz

Icont/IN = 141% - (T - 40 °C) × 2.50%

Icont/IN = 123% - (T - 40 °C) × 2.84%

8 kHz

Icont/IN = 136% - (T - 40 °C) × 3.36%

Icont/IN = 106% - (T - 40 °C) × 3.13%

16 kHz

Icont/IN = 101% - (T - 40 °C) × 3.48%

not possible