Profile value connection
Parameter | Index | Possible values | Meaning |
|---|---|---|---|
Maximum positive speed | 8377.001 | 0hex | Local value |
A20A7hex | Application limit – positive speed | ||
1E20A2hex | Fixed setpoints – speed | ||
Maximum negative speed | 8377.011 | 0hex | Local value |
B20A7hex | Application limit – negative speed | ||
1E20A2hex | Fixed setpoints – speed | ||
Maximum acceleration | 8377.021 | 0hex | Local value |
C20A7hex | Application limit – acceleration | ||
1F20A2hex | Fixed setpoints – speed | ||
Maximum deceleration | 8377.031 | 0hex | Local value |
D20A7hex | Application limit – deceleration | ||
2020A2hex | Fixed setpoints – speed | ||
Jerk time | 8377.041 | 0hex | Local value |