P872 Setpoint description PO3

P872 Setpoint description PO3

No function

 

You can use P873 – P875 to define the content of process input data words PI1 – PI3. This definition is necessary so MOVITRAC® B can allocate the appropriate actual values.

The following PI assignments are available:

Assignment

Description

0 / No function

The content of the process input data word is 0000hex

1 / Actual speed

Current speed actual value of the drive in rpm

2 / output current

Momentary active current of the inverter in % of IN.

3 / Active current

Momentary output current of the inverter in % of IN

6 / Status word 1

Status information of the inverter

7 / Status word 2

Status information of the inverter

8 / Actual speed %

Momentary actual speed value in % of P302

9 / IPOS® PI data

IPOS® process input data

10 / PI controller actual value %

Actual value of the PI controller