Parameter group 85. actual speed value scaling
Scaling actual speed value defines a user-specific display parameter P001 User display. For example, the user display is to be shown in 1/s. Such a setting requires a scaling factor of 1/60. This means the numerator scaling factor has to be set to "1" and the denominator scaling factor to 60. The scaling unit 1/2 is entered in P852 User-defined unit.
The following figure shows an example of the scaling actual speed value:
Additional information