Parameter group 87. Process data parameter setting

For further information, refer to the manual "MOVITRAC® B communication"

You can use P870 – P872 to define the content of process output data words PO1 – PO3. This definition is necessary so MOVITRAC® B can allocate the appropriate setpoints.

The following PO assignments are available:

Response

Description

0 / No function

The content of the process output data word is ignored

1 / Setpoint speed

Speed setpoint entry in rpm.

5 / Max. speed

Maximum speed (P302)

8 / Ramp

Ramp time for setpoint selection (P130 / P131).

9 / Control word 1

Control signals for start/stop, etc.

10 / Control word 2

Control signals for start/stop, etc.

11 / Setpoint speed %

Selection of a speed setpoint in % of P302

12 / IPOS® PO data

Specification of a 16-bit coded value for IPOSplus®

13 / PI controller setpoint %