OSS21C function module

Using these parameters, you can define, among other things, the following:

  • Alarm behavior
  • Universal behavior

DS: data set for access via CPU, PROFIBUS and PROFINET

IX: index for access via CANopen

SX: subindex for access via EtherCAT® with index 3100h + EtherCAT slot.

Name

Number of bytes

Function

Default

DS

IX

SX

DIAG_EN

1

Diagnostic alarmTransfer this parameter in STOP state only.

00h

00h

3100h

01h

IDX_1

2

Universal parameter 1: index

00h

80h

3101h -

3102h

02h

SUBIDX_1

2

Universal parameter 1: subindex

00h

80h

3103h -

3104h

03h

DATA_1

4

Universal parameter 1: value

00h

80h

3105h -

3108h

04h

IDX_2

2

Universal parameter 2: index

00h

81h

3109h -

310Ah

05h

SUBIDX_2

2

Universal parameter 2: subindex

00h

81h

310Bh -

310Ch

06h

DATA_2

4

Universal parameter 2: value

00h

81h

310Dh -

3110h

07h

IDX_3

2

Universal parameter 3: index

00h

82h

3111h -

3112h

08h

SUBIDX_3

2

Universal parameter 3: subindex

00h

82h

3113h -

3114h

09h

DATA_3

4

Universal parameter 3: value

00h

82h

3115h -

3118h

0Ah

IDX_4

2

Universal parameter 4: index

00h

83h

3119h -

311Ah

0Bh

SUBIDX_4

2

Universal parameter 4: subindex

00h

83h

311Bh -

311Ch

0Ch

DATA_4

4

Universal parameter 4: value

00h

83h

311Dh -

3120h

0Dh

IDX_5

2

Universal parameter 5: index

00h

84h

3121h -

3122h

0Eh

SUBIDX_5

2

Universal parameter 5: subindex

00h

84h

3123h -

3124h

0Fh

DATA_5

4

Universal parameter 5: value

00h

84h

3125h -

3128h

10h

IDX_6

2

Universal parameter 6: index

00h

85h

3129h -

312Ah

11h

SUBIDX_6

2

Universal parameter 6: subindex

00h

85h

312Bh -

312Ch

12h

DATA_6

4

Universal parameter 6: value

00h

85h

312Dh -

3130h

13h

IDX_7

2

Universal parameter 7: index

00h

86h

3131h -

3132h

14h

SUBIDX_7

2

Universal parameter 7: subindex

00h

86h

3133h -

3134h

15h

DATA_7

4

Universal parameter 7: value

00h

86h

3135h -

3138h

16h