Fault 150 Controller firmware – general device fault
Subfault: 150.1 Description: Unknown fault | ||
|---|---|---|
| Response: No response | |
Cause | Measure | |
MOVI-C® CONTROLLER firmware detected a severe fault that cannot be attributed to a precise device fault. | Check the log files for new entries with the severity "fault" or "exception" for further information. It might be necessary to activate the storage area of the log files in the file system of the MOVI-C® CONTROLLER. Acknowledging the fault will restart the MOVI-C® CONTROLLER. If the problem is still present, contact SEW-EURODRIVE Service. | |
Subfault: 150.2 Description: Restart after exception handling | ||
|---|---|---|
| Response: No response | |
Cause | Measure | |
The MOVI-C® CONTROLLER performed an exception handling followed by a restart. This can be caused by impermissible memory access, for example. | During exception handling, the MOVI-C® CONTROLLER stored a log file in the file system with further details on the exception. You can use the log file to eliminate the fault or use the information of the log file when contacting SEW-EURODRIVE Service. Acknowledging the fault will restart the MOVI-C® CONTROLLER. | |
Subfault: 150.3 Description: Faulty booting | ||
|---|---|---|
| Response: No response | |
Cause | Measure | |
Failed to start the MOVI-C® CONTROLLER properly. The configuration of the MOVI-C® CONTROLLER firmware might be wrong or corrupt. | Check the log files for new entries with the severity "fault" or "exception" for further information. It might be necessary to activate the storage area of the log files in the file system of the MOVI-C® CONTROLLER. Acknowledging the fault will restart the MOVI-C® CONTROLLER. If the problem is still present, contact SEW-EURODRIVE Service. | |
Subfault: 150.4 Description: Fault in early booting phase | ||
|---|---|---|
| Response: No response | |
Cause | Measure | |
Failed to start the MOVI-C® CONTROLLER properly in the early booting phase due to faults. | Check the log files for new entries with the severity "fault" or "exception" for further information. It might be necessary to activate the storage area of the log files in the file system of the MOVI-C® CONTROLLER. If the software packages are corrupt, load original SEW-EURODRIVE software packages onto the removable storage device again. Acknowledging the fault will restart the MOVI-C® CONTROLLER. If the problem is still present, contact SEW-EURODRIVE Service. | |