Assignment of terminal X2_A with MMF..CO.. design

For motors with digital interface (MOVILINK® DDI interface).
As an alternative, also for motors without digital interface (MOVILINK®-DDI interface), but then without connecting a motor temperature sensor.

Terminal

No.

Marking

Connection

Depending on the brake control

Brake control /B
for AC brakes
100 – 525 V.

Brake control /BES for DC brakes
24 V.

X2_A
Terminals for
motor and brake

 

For MMF...CO design

 

For motors
with digital interface (MOVILINK® DDI)

D

White

Connection of brake 14

  • Brake coil: White
  • Hybrid cable: Violet (D)

Connection of brake +

  • BK, BZ brake coil: Red
  • BP brake coil: Yellow
  • Hybrid cable: Violet (D)

C

White

Connection of brake 13

  • Brake coil: Red
  • Hybrid cable: Pink (C)

Reserved

  • Hybrid cable: Pink (C)

B

White

Connection of brake 15

  • Brake coil: Blue
  • Hybrid cable: Orange (B)

Reserved

  • Hybrid cable: Orange (B)

A1

White

Reserved

  • Hybrid cable: Yellow (A)

Connection of brake -

  • BK, BZ brake coil: Blue
  • BP brake coil: Yellow
  • Hybrid cable: Yellow (D)

T2

White

Reserved

U

Gray

Motor connection, phase U

V

Gray

Motor connection, phase V

W

Gray

Motor connection, phase W

Wiring diagrams