SS2-r – Safe Stop 2 with monitoring of the deceleration ramp

When the SS2-r safety sub-function is active, the motor is brought to a standstill electrically. The deceleration is monitored. The position must be safely monitored after standstill (SOS function according to EN 61800‑5‑2). The STO safety sub-function will be triggered if the deceleration value is exceeded while stopping or movement occurs in an idle state. After the STO safety sub-function has been triggered, the idle state has to be ensured, for example, by a mechanical brake.

The SS2-r safety sub-function corresponds to a controlled stop of the drive according to EN 60204‑1, stop category 2.

=

SS2-r safety sub-function monitored

 

=

STO safety sub-function active

v

=

Speed

t

=

Time

t1

=

Point in time when SS2-r is activated and motor deceleration is triggered.

t2

=

Point in time at which SOS is activated.