Standby mode
The energy-saving function standby operation is designed for periods in which the operation is paused.
If necessary, activate standby operation with a binary input or a bit of the control word.
Switching from standby operation to operation takes only approx. 500 ms. This is the main difference to switching off the DC 24 V supply voltage. This short changeover time reduces energy consumption even in short pauses.
The following functions are deactivated in standby mode:
- Power section control
- Fan of the power heat sink (if present)
- Binary outputs
- STO function
- CBG functions (display: "standby operation")
- Changing parameters
- Updating the firmware
- Reset to delivery state
- Drive and motor startup
- Optional:
- Switch off the supply of the encoder and the safety card
- Encoder evaluation
The bus communication remains active without restrictions in standby operation.