Standby mode

The energy-saving function standby operation is designed for periods in which the operation is paused.

If necessary, activate standby operation with a binary input or a bit of the control word.

Switching from standby operation to operation takes only approx. 500 ms. This is the main difference to switching off the DC 24 V supply voltage. This short changeover time reduces energy consumption even in short pauses.

The following functions are deactivated in standby mode:

  • Power section control
  • Fan of the power heat sink (if present)
  • Binary outputs
  • STO function
  • CBG functions (display: "standby operation")
  • Changing parameters
  • Updating the firmware
  • Reset to delivery state
  • Drive and motor startup
  • Optional:
    • Switch off the supply of the encoder and the safety card
    • Encoder evaluation

The bus communication remains active without restrictions in standby operation.