FCB 25 Motor parameter measurement
FCB 25 is used for determining the necessary parameters from the electric equivalent wiring diagram during startup.
The nameplate data of the connected motor is required for motor parameter measurement.
After the motor parameter measurement has been completed, the motor is completely started up electrically. Values that are not yet final at this stage, such as maximum speed and maximum torque, are estimated. The values have to be corrected at a later time to reach the full performance of the motor.
The FCB 25 should only be called up if no output filter is used. Otherwise, the FCB provides incorrect results because of the output filter inductance.