Configuring additional process values of the inverter

Do the following to configure the additional process values of the inverter:

  1. In the "Basic settings" configuration menu under "Functions used", open the configuration of the software module and activate the function "Additional process values of the inverter".
    • Further setting options for configuring the additional process values of the inverter are displayed.
  2. Use the "Number of additional process values" setting option to specify how many additional process values are to be transferred.
    • The free process data words can now be edited.
  3. Configure the process data words as required. To reset the existing configuration to the "No function" value, click [Reset free process data].