FCB 05 Speed control

INFORMATION

For axes without encoder, the stop by setpoint function must be enabled and both the stop setpoint and the start offset must be set. The brake will then only release when "speed control" mode is selected and the specified setpoint speed is greater than the stop setpoint + start offset.

Parameter name

Description

Stop by setpoint function

Activation

Activation of the stop by setpoint function

Index: 8570.1

Stop setpoint

Setpoint of the stop by setpoint function

The drive is stopped when the speed setpoint drops below the stop setpoint.

Index: 8570.2

Start offset

Start offset of the stop by setpoint function

The drive is only enabled when the setpoint exceeds the enable setpoint (stop setpoint + start offset).

Index: 8570.3