Reference signals

Parameter group

Description

Comparison of setpoint/actual speed values

Half window width

Speed setpoint window

Index: 8324.3

IEC name: -

In position

Window width

If the difference between actual and setpoint positions is less than or equal to half this value, the "in position" signal is set.

Index: 8331.1

IEC name: -

Hysteresis

Target position hysteresis. If the window width is exceeded, the "in position" signal remains set until this value is exceeded.

Index: 8331.2

IEC name: -

Actual target position in user units

Actual target position in user units

Index: 8331.3

IEC name: -