Control word
INFORMATION
For the behavior of the drive at an idle state, refer to the information in the chapter Control functions.
Bit | Function | PD | V/P | Description |
---|---|---|---|---|
0 | Enable/emergency stop | PO 1.0 | V/P |
|
1 | Enable/application stop | PO 1.1 | V/P |
|
2 | Reserved | PO 1.2 | V/P | - |
3 | Release brake (without enable) | PO 1.3 | V/P | If required, activate this function using parameter 8501.2 (Release brake/DynaStop® with FCB 01 – enable). |
4 | Jog positive | PO 1.4 | P | Signal for moving the drive in positive direction in jog mode. |
5 | Jog negative | PO 1.5 | P | Signal for moving the drive in negative direction in jog mode. |
6 | Apply relative position | PO 1.6 | P | Apply relative target position in relative positioning mode (401). This signal is ineffective for all the other operating modes. |
7 | Start/stop with fieldbus ramp | PO 1.7 | V/P |
|
8 | Fault reset | PO 1.8 | V/P | Reset of fault messages with the positive edge of the signal. |
9 | Reserved | PO 1.9 | V/P | - |
10 | Activate drive train 2 | PO 1.10 | V/P |
|
11 | Reserved | PO 1.11 | V/P | - |
12 | Disable SW limit switches | PO 1.12 | P | If software limit switches are activated and configured in the configuration.
|
13 | Activate output stage inhibit | PO 1.13 | V/P |
|
14 | Activate standby mode | PO 1.14 | V/P |
Standby mode can be activated only when the output stage is inhibited. |
15 | MOVIKIT® Handshake In | PO 1.15 | V/P | This signal is copied internally to status word bit 15 (MOVIKIT® Handshake Out). If the copying operation fails ("Handshake Out" remains constant with changing "Handshake In" signal), the device-internal processing of the MOVIKIT® software module is disrupted. |