DIP switch S1/5

Motor protection switched on / switched off

When the MOVIMOT® inverter is installed (close to) the motor, the motor protection must be deactivated.

To ensure motor protection, a TH (bimetallic thermostat) must be used. The TH opens the sensor circuit when the nominal response temperature is reached (see field distributor manual).