MOVI-DPS® series

  1. Using a discharge unit from SEW-EURODRIVE, discharge the MOVI-DPS® storage bundle via interface X2381 of the MOVI-DPS® EKK energy and power interface. Observe the operating instructions of the discharge unit.
  2. Briefly short-circuit the MOVI-DPS® storage bundle immediately after discharge. To do so, connect the short-circuit connector to interface X2381 at the MOVI-DPS® EKK energy and power interface.