Cam switch
This function mirrors parameterizable position ranges onto the process input data word (PI 11). The corresponding bits (PI 11:X) become active under the following conditions:
- PI 11:X = "TRUE" = right limit ≤ actual position ≥ left limit
Response time:
The longest response time to be assumed depends on the number of cam positions used and the device used:
- MOVIDRIVE® technology:
- Response time ≤ 4 ms * Number of cams used
- MOVITRAC® Generation C and decentralized devices:
- Response time ≤ 8 ms * Number of cams used