Underlying standards
The safety assessment is based on the following standards:
EN 62061 EN 61508 | EN 61800‑5‑2 | EN ISO 13849 | |
|---|---|---|---|
BY.. | – | – | ✔ |
BZ.. | – | – | ✔ |
Safety integrity level 3 (SIL 3) or performance level e (PL e) can be achieved if a functionally safe motor option is suitably integrated into a safety system. The requirements, e.g. regarding the system architecture, any necessary diagnostics, and failure probabilities, are to be implemented in accordance with the normative specifications and this documentation.
If the safety system with safety brakes is to be evaluated in accordance with SIL, the necessary verification must be provided by the customer.