Reference travel
Parameter designation | Description |
|---|---|
Reference travel | |
Reference travel type INFORMATION: When selecting the reference travel types with limit switches, ensure that the limit switch evaluation configured in the configuration menu Limit switches is activated. |
|
Index: 50007.1 | |
IEC name: ProfileGeneration.Homing.Config.eReferenceTravelType | |
Source of reference cam for axis group member 1 INFORMATION: Only visible for reference travel types "Reference cam – negative end", "Reference cam – positive end", "Reference cam flush – limit switch positive" and "Reference cam flush – limit switch negative". |
|
Index: 50007.31 | |
IEC name: – | |
Reference offset per member | Activate specification of an individual reference offset for each axis group member. The following requirements must be met to use the parameter:
|
Index: 50010.52 | |
IEC name: – | |
Reference offset INFORMATION: Only visible if "Reference offset per member" is activated. | Setting the reference offset for the respective axis group member (in user units). |
Index: 50010.53-56 | |
IEC name: – | |
Reference offset | Setting the reference offset for the entire axis group (in user units). Is required, for example, when the cam is not located at machine zero. |
Index: 50007.2 | |
IEC name: ProfileGeneration.Homing.Config.lrReferenceOffset | |
Search speed INFORMATION: Only visible if a reference travel type with travel is selected. | Search speed of reference travel (in user units) |
Index: 50007.4 | |
IEC name: ProfileGeneration.Homing.Config.lrSearchVelocity | |
Retraction speed INFORMATION: Only visible if a reference travel type with travel is selected. | Retraction speed of reference travel (in user units) |
Index: 50007.5 | |
IEC name: ProfileGeneration.Homing.Config.lrClearVelocity | |
Acceleration INFORMATION: Only visible if a reference travel type with travel is selected. | Acceleration of reference travel (in user units) |
Index: 50007.6 | |
IEC name: ProfileGeneration.Homing.Config.lrAcceleration | |
Deceleration INFORMATION: Only visible if a reference travel type with travel is selected. | Deceleration of reference travel (in user units) |
Index: 50007.7 | |
IEC name: ProfileGeneration.Homing.Config.lrDeceleration | |
Jerk INFORMATION: Only visible if a reference travel type with travel is selected. | Jerk of reference travel (in user units) |
Index: 50007.8 | |
IEC name: ProfileGeneration.Homing.Config.lrJerk | |
Advanced settings | |
Go to home position | Activates or deactivates homing |
Index: 50007.9 | |
IEC name: ProfileGeneration.Homing.Config.xMoveToStartPosition | |
Home position with skew compensation INFORMATION: Visible only if "Go to home position" is activated. | If a reference offset for each member as well as a reference travel type based on limit switches is used, homing must be performed without skew compensation. Otherwise, the compensation movement after reaching the hardware limit switch could trigger the switch again. |
Index: 50010.51 | |
IEC name: – | |
Home position INFORMATION: Visible only if "Go to home position" is activated. | Position that is automatically moved to after referencing (in user units) |
Index: 50007.10 | |
IEC name: ProfileGeneration.Homing.Config.lrStartPosition | |
Homing speed INFORMATION: Visible only if "Go to home position" is activated. | Speed for moving to the home position after referencing (in user units) |
Index: 50007.11 | |
IEC name: ProfileGeneration.Homing.Config.lrStartPosVelocity | |
Encoder referencing INFORMATION: Only visible in expert mode. |
|
Index: 50010.50 | |
IEC name: ProfileGeneration.Homing.Config.HomingAG.xActivateEncoderHoming | |
Source of referenced signal INFORMATION: Only visible in expert mode. | Selection of the source of the "referenced" signal:
|
Index: 50007.20 | |
IEC name: ProfileGeneration.Homing.Config.HomingAG.eSourceForReferencedSignal | |
Save referencing to non-volatile memory INFORMATION: Only visible in expert mode. | Selection of the source of the "referenced" signal:
|
Index: 50007.12 | |
IEC name: – | |
Readjustment | |
Readjustment INFORMATION: Readjustment is only visible in the reference travel types "Positive limit switch" and "Negative limit switch". |
When readjustment is active, after a HW limit switch has been hit, the limit switches of the other members are also hit until all limit switches have been hit. |
Index: 50010.30 | |
IEC name: ProfileGeneration.Homing.Config.HomingAG.Readjustment.xActivate | |
Monitoring time INFORMATION: Only visible when "readjustment" is active. | Time permitted for readjustment in [s] If this time period is exceeded, a fault is displayed. To deactivate the function, specify a value of "0". Default value: 0 |
Index: 50010.31 | |
IEC name: ProfileGeneration.Homing.Config.HomingAG.Readjustment.lrSafetyTime | |
Monitoring distance INFORMATION: Only visible when "readjustment" is active. | Distance permitted for readjustment (in user units) If this distance is exceeded, a fault is displayed. To deactivate the function, specify a value of "0". Default value: 0 |
Index: 50010.32 | |
IEC name: ProfileGeneration.Homing.Config.HomingAG.Readjustment.lrSafetyDistance | |
Selection of HW limit switches for readjusting axis group members | |
Select which of the positive and negative limit switches is to apply for readjustment of the respective axis group members. | |
Index: 50010.40-43 | |
IEC name: ProfileGeneration.Homing.Config.HomingAG.Readjustment.usiLSNegativeAGMember1-4/usiLSPositiveAGMember1-4 | |