Permitted module combinations
The MDP90A.. power supply modules must only be connected to the following modules in the DC link:
- MDE90A.. DC/DC converter module (size 2 – 4 for MDP90A..)
- MDA90A.. single-axis modules
- MDD9.A.. double-axis modules
- Capacitor modules MDC90A-0001/0002.. for two-row setup
The following modules may be used in an axis system, but must not be connected in the DC link:
- MDS90A.. switched-mode power supply module
- Master module UHX45A/MDM90A
An MDP90A.. power supply module can be combined with an MDE90A.. DC/DC converter module. For further information, refer to chapter MDE90A.. DC/DC converter module.