Error responses

The following table describes the shut-off responses to faults:

Error response

Description

No response

The inverter ignores the event.

Warning with self reset

The inverter issues a warning message with self-reset.

The error is automatically reset after the cause of the error is eliminated.

Warning

The inverter issues a warning message.

Application stop (with output stage inhibit)

The inverter stops with the delay set for the application limit (index 8357.13).

If n = 0: Brake "applied" and output stage "off".

Application stop (with output stage inhibit) with self-reset

Emergency stop (with output stage inhibit)

The inverter stops with the set emergency stop deceleration.

(Index 8357.20)

Emergency stop (with output stage inhibit) with self-reset

Inhibit output stage with self-reset

The output stage is deactivated and the brake is applied.

Inhibit output stage

Self-reset means: Eliminating the cause of the error results in the acknowledgment of the error. The inverter automatically resumes the operation performed before the error. The drive can restart automatically.