Parameterizable faults

Parameterizable faults

Description

Index no.

Possible fault response

Line phase failure

Here you can set the device response to a line phase failure.

8622.4

  • No response
  • Warning
  • Emergency stop (+output stage inhibit)
  • Output stage inhibit

Power failure

Here you can set the device response to a power failure.

8622.9

  • No response
  • Warning
  • Emergency stop (+output stage inhibit)
  • Output stage inhibit

Fieldbus – timeout

Here you can set the device response to a timeout on the EtherCAT®/SBusPLUS (timeout period, Index 8455.3).

8622.6

  • Warning
  • Warning with self-reset
  • Emergency stop (+output stage inhibit)
  • Output stage inhibit
  • Emergency stop (+output stage inhibit) with self-reset
  • Output stage inhibit with self-reset

Line undervoltage

Here you can set the device response to a line undervoltage.

8622.23

  • No response
  • Warning

External fault

Here you can set how the device should respond to a fault message from an external fault source.

 

  • No response
  • Warning
  • Emergency stop (+output stage inhibit)
  • Output stage inhibit