Process sequence and signal states
INFORMATION

For the behavior of the drive at idle state, observe the information in the "Stop functions" section in the parameterization of the inverter under [Functions] > [Monitoring functions] > [Control functions].
No. | Process | PD | Signal states |
|---|---|---|---|
[1] General enable | PO 1:0 = "1" Enable/emergency stop | PO 1:0 |
|
PO 1:1 = "1" Enable/application stop | PO 1:1 |
| |
PO 1:13 = "0" Output stage inhibit (signal with highest priority) | PO 1:13 |
| |
[1] | Activating the "Feed-in" setpoint application mode | PO 6 | 600 (decimal) |
Activating the positive direction of movement | PO 1:4 | "1": The drive accelerates to the rapid speed specified via PO 2/fixed setpoint using the value specified via PO 3/fixed setpoint. | |
"Start" selection | PO 1:7 | ||
[1] to [2] and the [5] to [6] | "Rapid speed active" | PI 7:0 | "1": Setpoint speed corresponds to rapid speed specified via PO 2/fixed setpoint. |
[2] | "Sensor F/S positive" trips |
| Edge change detected |
[2] to [3] | "Creep speed active" | PI 7:1 | "1": Drive decelerates with the deceleration specified via PO 4/fixed setpoint. The setpoint speed corresponds to the creep speed specified via PO 7/fixed setpoint. |
[3] | "Sensor stop positive" trips |
| Edge change detected |
[3] to [4] | Deceleration stop | PI 7:1 | "1": Drive decelerates up to standstill with the stop deceleration specified via PO 8/fixed setpoint. |
[5] | Activating the "Feed-out" setpoint application mode | PO 6 | 601 (decimal) |
[6] to [7] | "Start" removal | PI 1:7 | "1": Drive decelerates up to standstill with the deceleration specified via PO 4/fixed setpoint. |