Process sequence and signal states
INFORMATION

For the behavior of the drive at idle state, observe the information in the "Stop functions" section in the parameterization of the inverter under [Functions] > [Monitoring functions] > [Control functions].
No. | Process | PD | Signal states |
|---|---|---|---|
[1] General enable | PO 1:0 = "1" Enable/emergency stop | PO 1:0 |
|
PO 1:1 = "1" Enable/application stop | PO 1:1 |
| |
PO 1:13 = "0" Output stage inhibit (signal with highest priority) | PO 1:13 |
| |
[1] | Activation of "jog mode" application mode | PO 6 | 100/101 (decimal) |
Dynamics parameters are applied (also during ongoing movement) | PO 2 PO 3 PO 4 | Setpoint speed Acceleration Deceleration | |
[2] – [4] | Activation of positive jog direction | PO 1:4 |
|
[5] – [7] | Activation of negative jog direction | PO 1:5 |
|
[3] – [4] and [6] – [7] | If the actual speed lies within the configured window width, the feedback "Setpoint/actual speed comparison" is issued. | PI 1:11 |
|