Synchronous motors in CFC control mode
Do not configure the maximum speed higher than the rated speed of the motor.
SEW-EURODRIVE recommends a PWM frequency of 8 kHz or 16 kHz for the following motors:
- CMP40/..50/..63 for speeds above 4500 min-1
- CMP71/..80/..100 for speeds above 3000 min-1
- CM3C63/..71/..80/..100 for speeds above 3000 min-1
SEW‑EURODRIVE recommends using the following temperature sensors:
- KTY84 – 130 (SEW‑EURODRIVE designation: KY)
- Pt1000 (SEW-EURODRIVE designation: PK)