Additional functions

Variable jerk time

Word

Bit

Function

PI 9

Reserved

0 – 15

Reserved

Variable torque limit via process data – status word for torque limit

Word

Bit

Function

PI 9without using the variable jerk time

PI 10when using the variable jerk time

Status word

0

Torque limit via process data active

1

Monitoring inactive

2

Torque limit reachedWith active torque limit via process data, this bit indicates whether the torque limit specified via process data has been reached. In torque control operating mode (800), the display is based on the internal torque limit which occurs when the calculated limit speed is reached.

Parameter channel via process data

INFORMATION

The amount of previously configured process data must be added to the specified process data word number.

Word

Bit

Function

PI 1

Status word

8

Read service selected

9

Write service selected

13

Service active

14

Service completed

15

Service failed

PI 2

Index

 

Index of the parameter that is being read/written

PI 3

Offset

0 – 7

Offset of the parameter that is being read/written

Subindex

8 – 15

Subindex of the parameter that is being read/written

PI 4/5

Value

 

Read value/Error code