Status word

Bit

Function

PD

Description

...

...

...

...

8

Error

PI 1:8

  • "1": Error present
  • "0": No error present

Errors can be reset using process data word PO 1.8 "Error reset".

9

Warning

PI 1:9

  • "1": Warning present
  • "0": No warning present

Warnings can be reset using process data word PO 1.8 "Error reset".

Warnings that are parameterized as warnings with self-reset will delete themselves when the reason for the warning no longer exists. In this case, no reset is necessary.

For more information, refer to the product manual of the respective device.

...

...

...

...

12

SW limit switches inactive

PI 1:12

The signal is active if software limit switches are configured and activated and one of the following conditions is fulfilled:

  • Bit PO 1:12 "Deactivate SW limit switches" is set.
  • Both software limit switches were set to the value "0".