P131 / P141 ramp t11 / t21 down
P131 / P141 ramp t11 / t21 down
P131 Ramp t11 down CW / P141 Ramp t21 down CW
Setting range: 0 – 2 – 2000 s
The ramp times refer to a setpoint step change of Δn = 3000 rpm. The ramp takes effect when the speed setpoint is changed and the enable signal is revoked via the CW/CCW terminal.
Setting range: 0 – 2 – 2000 s; deceleration ramp