Data backup with FBG11B
Use the FBG11B keypad to download parameter data from the MOVITRAC® B to the keypad or copy from the keypad to MOVITRAC® B.
Check that the required data set has been copied to the inverter.
Data backup with FBG11B
After copying data, the MOVITRAC® B is inhibited. The inhibited status is indicated by a flashing STOP in the status display. The status LED also slowly flashes yellow.
You can revoke the inhibit by taking one of the following measures:
- Press the RUN key on the FBG11B.
- Switch off the power supply, wait for 10 seconds and switch the power back on.