Configuring a project

The following figure shows the described project setup for connecting 4 axis group members. Create such a project in MOVISUITE®.

Configure the encoder evaluation of the exes as follows when doing this:

Level

Name of level

Encoder evaluation: External encoders

Encoder evaluation: Position controller

Encoder evaluation: External encoder settings

1

Higher-order
MultiAxisController

("TravelAxis")

Encoder source:
"Motor encoder and external encoder"

Type: "EtherCAT®encoder" with " EtherCAT®encoder source" station 1: "Name of MOVIKIT® EncoderInterface node"

2

Subordinate
MultiAxisController

("xMAC1" and "xMAC2")

Do not activate an external encoder

Encoder source:
"Motor encoder"

3

Subordinate
MultiMotion axes ("xAxis11-12" and
"xAxis21-22")

Configuring a drive train with an external encoder

Activate position evaluation at the motor encoder in the drive train

The external encoder must be incorporated via the separate MOVIKIT® EncoderInterface ("EncoderInterface"). The MOVIKIT® EncoderInterface does not require any additional license, and must be positioned on the left next to the MOVIKIT® StackerCrane (see figure). Configure the MOVIKIT® EncoderInterface as follows:

Parameter

Value

Type

Advanced

Axis name

Axis with external encoder

Number of decimal places

Same number as associated MultiMotion axis

Generate the IEC project with MOVISUITE® after completing the configuration. See Generating an IEC project.