Data management via File over EtherCAT® (FoE)
If the EtherCAT® master supports the FoE service (see manufacturer documentation of the EtherCAT® master), the parameter set of the inverter can be saved on the EtherCAT® master or on the engineering PC. The saved data can also be reloaded into the inverter. Thus, a complete device replacement can be carried out by the data management without repeating startup.
The parameter set contains the following data:
- Motor data and startup data
- Safety-related parameterization, if present
- Scope data, if present
Data management can be performed either via the engineering tool of the EtherCAT® master or from the control program of the PLC using a function block. In both cases, user interfaces are required on the inverter.
The following user interfaces are defined for the inverters of the MOVI-C® modular automation system:
Inverter | Data management | |
|---|---|---|
All parameters | Comparable parameters | |
|
|
|
MOVIDRIVE® modular MDD.. double-axis module – axis 2 |
|
|
INFORMATION