Work steps for MOVIGEAR® classic MGF..1-..C

NOTICE

Loss of the guaranteed degree of protection.
Damage to property.
  • When the cover is removed from the connection box, the cover and the wiring space must be protected from humidity, dust or foreign particles.

Replace the gasket of MOVIGEAR® classic MGF..1-..C as follows:

  1. Perform the steps described in the chapter Preliminary work for inspection and maintenance.
  2. Loosen the screws of the cover and remove it.
  3. NOTICE! Loss of the guaranteed degree of protection. Possible damage to property. Make sure that the sealing surfaces are not damaged when removing the gasket. Remove the old gasket completely from the connection box.
  4. CAUTION! Risk of injury due to sharp edges. Cutting injuries. Use protective gloves when cleaning. Ensure that work is carried out by trained specialists only. Carefully clean the sealing surfaces of the connection box and the cover.
  5. Place the new gasket on the connection box and fix it in position with the retaining cams [1].
  6. [1]

    Retaining cams

  7. Check the installation and startup of the drive unit based on the applicable operating instructions.
  8. Place the cover back onto the connection box and secure it.
    • Proceed as follows when installing the cover: Insert/screw in the screws and tighten them step by step in diametrically opposite sequence with a tightening torque of 6.0 Nm.