Work steps to replace the seal
NOTICE
Loss of the guaranteed degree of protection.
Damage to property.
- When the interface module is removed from the motor, the interface module and motor must be protected from humidity, dust, and foreign particles.
- Make sure that the interface module has been mounted properly.
Replace the seal of the MOVIMOT® performance ELV as follows:
- Perform the steps according to chapter Preliminary work regarding inspection and maintenance.
- Undo the screws of the interface module and remove it.
- Loosen the used gasket by levering it off the retaining cams.
- Disassembly is easier if you adhere to the sequence shown in the following figure.
- Remove the old seal completely from the motor.
- Carefully clean the sealing surfaces of the motor and interface module.
- Place the new seal on the motor and fix it with the retaining cams. Installation is facilitated if you follow the illustrated order.
- Place the interface module back on the motor and secure it.