FCB 09 Position control

Parameter group

Description

In position

Window width

The "In position" signal is set when the difference between the actual position and the setpoint position is smaller than half this value.

Index: 8331.1

Hysteresis

Target position hysteresis. When the position window is left, the "In position" signal is maintained until this value is exceeded.

Index: 8331.2

Lag error

Lag error window

Specifies from which lag error the drive signals a fault (drive train 1).

The "Lag error window" parameter takes effect for FCB 09 and FCB 26.

Information: The setting applies to FCB 09 and FCB 26. For FCB 20 Jog mode, for example, a separate lag error window is available.

Index: 8509.4

Response to positioning lag error

Specifies how the device responds to a lag error (lag error window exceeded, index 8509.4).

The "Response to positioning lag error" parameter takes effect for FCB 09, FCB 10, and FCB 26.

Index: 8622.3