Derating due to the ambient temperature
The following derating applies at ambient temperatures of > 40 °C:
- Reduction of the continuous power by 4% per 10 K
- Reduction of the tripping current by 2% per 10 K
Do not exceed a maximum ambient temperature of 80 °C.