Hardware limit switches
INFORMATION
Wire the hardware limit switches to the digital inputs DI 02 (positive) and DI 03 (negative) of the inverter. Also select "No function" for digital inputs DI 02 and DI 03 in the "Inputs/outputs" configuration menu of the inverter.
Parameter name | Value |
---|---|
Hardware limit switches | |
Logical operation of HW limit switches |
|
Index: 50015.1 | |
IEC name: LimitSwitchEvaluation.Config.eOperation | |
Debouncing time | Debouncing time for the limit switches in [s] Default value: 0.2 |
Index: 50015.3 | |
IEC name: LimitSwitchEvaluation.Config.lrLimitSwitchDebouncingTime | |
Fault response | |
Fault response |
|
Index: 50015.2 | |
IEC name: LimitSwitchEvaluation.Config.eReaction | |
Take account of HW limit switches | |
Select the positive and negative hardware limit switches that are applicable to monitoring. The number of sliders displayed depends on the number of subordinate axis group members. | |
Index: Negative: 50015.11-18; positive: 50015.21-28 | |
IEC name: LimitSwitchEvaluation.Config.axActivateLSNegative[1]...[4] LimitSwitchEvaluation.Config.axActivateLSPositive[1]...[4] |