Plug connector positions of electronics cover DFC with safe digital inputs

The following figure shows an example of the plug connector positions:

Plug connectors

Function

X5133_1Only for electronics cover in connection configuration DFC.0.. and DFC.1..

Digital inputs DI01 and DI02

X5133_2Only for electronics cover in connection configuration DFC.0.. and DFC.1..

Digital inputs DI03 and DI04

X5133_3Only for electronics cover in connection configuration DFC.0.. and DFC.1..

Digital inputs/outputs DIO01 and DIO02

X4233_1Only for electronics cover in configuration DFC.0..

Fieldbus/Ethernet interface, port 1

X4233_2Only for electronics cover in configuration DFC.0..

Fieldbus/Ethernet interface, port 2

X5601_1

Safe digital inputs F‑DI00 and F‑DI01

X5601_2

Safe digital inputs F‑DI02 and F‑DI03

X3301

Safe digital inputs for EI7C FS built-in encoder

With MOVIMOT® advanced, the built-in encoder is installed in the motor. The connection cable leads out of the connection box to plug connector X3301.

Do not unplug the mating connector plugged in at the factory.